{"product_id":"garmin-ondeck-relay-switch-12-v-dc","title":"Garmin OnDeck relay switch (12 V DC)","description":"\u003cp\u003eControl the boat remotely using the OnDeck™ hub and the relay switch. Add up to five switches to the OnDeck hub to stay in control. Check that the input power of the OnDeck hub works between 10 and 15.6 V DC to ensure compatibility with your system.\u003c\/p\u003e\n\u003ch3\u003eSpecifications:\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMisc\u003c\/td\u003e\n\u003ctd\u003eTo avoid potential damage to the relay switch, GTB 10 black box device, and device being switched, you must install this relay switch in a dry location.\n\u003ctable border=\"0\" cellspacing=\"0\" cellpadding=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature range\u003c\/td\u003e\n\u003ctd\u003eFrom -15° to 85°C (from 5° to 185°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage temperature range\u003c\/td\u003e\n\u003ctd\u003eFrom -40° to 155°C (from -40° to 311°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl voltage (coil)\u003c\/td\u003e\n\u003ctd\u003e7.8 to 15.6 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLoad power min. (contacts)\u003c\/td\u003e\n\u003ctd\u003e0.1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLoad power max. (contacts)\u003c\/td\u003e\n\u003ctd\u003eUp to 15 A at 10 to 16 Vdc\u003cbr\u003e\nUp to 9 A at 20 to 32 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c!-- sr-faq v=1 vendor=garmin source_sha256=f06b58ed99315b0f6a23400a720bb835f4f04e14add0aeab739ad3a5a943534c --\u003e\u003ch3\u003eFAQs\u003c\/h3\u003e\u003cdetails\u003e\u003csummary\u003eHow should the negative wire from the item be connected?\u003c\/summary\u003e\u003cdiv\u003e\u003cp\u003eConnect the negative wire from the item to the negative side of the power source to complete installation.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails\u003e\u003csummary\u003eAre there any specific safety precautions for installation?\u003c\/summary\u003e\u003cdiv\u003e\u003cp\u003eWear goggles, ear protection, disconnect vessel’s power and ensure proper grounding before starting installation.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails\u003e\u003csummary\u003eWhat fuse size is recommended for relay wiring?\u003c\/summary\u003e\u003cdiv\u003e\u003cp\u003eInstall a 1 Amp fuse on all relay controls at the positive input to the power source.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails\u003e\u003csummary\u003eWhere should the relay switch be installed for proper operation?\u003c\/summary\u003e\u003cdiv\u003e\u003cp\u003eThe relay switch must be installed in a dry location to avoid potential damage to the switch, GTB 10 device, and connected device.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails\u003e\u003csummary\u003eAre there mounting orientation requirements for the hub device?\u003c\/summary\u003e\u003cdiv\u003e\u003cp\u003eMount the device with connectors facing up on a horizontal surface or facing out on a vertical surface. Avoid connectors facing down or to the mounting surface.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails\u003e\u003csummary\u003eWhere should the relay switch be installed?\u003c\/summary\u003e\u003cdiv\u003e\u003cp\u003eThe relay switch must be installed in a dry location to avoid potential damage to the relay switch, GTB 10, and device being switched.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails\u003e\u003csummary\u003eDo relay connections require specific polarity?\u003c\/summary\u003e\u003cdiv\u003e\u003cp\u003eDo not connect control wires to the positive side of a power source; follow connection guidance for polarity.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails\u003e\u003csummary\u003eWhat mounting distance is required from other electronics or cables?\u003c\/summary\u003e\u003cdiv\u003e\u003cp\u003eYou must mount the device at least 102 mm (4 in.) from cables and other potential sources of interference.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails\u003e\u003csummary\u003eHow do I protect bare wire connections exposed to moisture?\u003c\/summary\u003e\u003cdiv\u003e\u003cp\u003eUse heat-shrink type butt connectors or other water-tight connections for bare wires exposed to moisture.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails\u003e\u003csummary\u003eAre there guidelines for extending IN\/OUT wires?\u003c\/summary\u003e\u003cdiv\u003e\u003cp\u003eIf you need to extend the IN\/OUT wires, use minimum of 24 AWG (0.08 mm²) wire.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails\u003e\u003csummary\u003eHow should unused connectors be protected?\u003c\/summary\u003e\u003cdiv\u003e\u003cp\u003eTo prevent corrosion, cover unused connectors with weather caps.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cscript type=\"application\/ld+json\"\u003e{\"@context\": \"https:\/\/schema.org\", \"@type\": \"FAQPage\", \"mainEntity\": [{\"@type\": \"Question\", \"name\": \"How should the negative wire from the item be connected?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Connect the negative wire from the item to the negative side of the power source to complete installation.\"}}, {\"@type\": \"Question\", \"name\": \"Are there any specific safety precautions for installation?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Wear goggles, ear protection, disconnect vessel’s power and ensure proper grounding before starting installation.\"}}, {\"@type\": \"Question\", \"name\": \"What fuse size is recommended for relay wiring?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Install a 1 Amp fuse on all relay controls at the positive input to the power source.\"}}, {\"@type\": \"Question\", \"name\": \"Where should the relay switch be installed for proper operation?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"The relay switch must be installed in a dry location to avoid potential damage to the switch, GTB 10 device, and connected device.\"}}, {\"@type\": \"Question\", \"name\": \"Are there mounting orientation requirements for the hub device?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Mount the device with connectors facing up on a horizontal surface or facing out on a vertical surface. Avoid connectors facing down or to the mounting surface.\"}}, {\"@type\": \"Question\", \"name\": \"Where should the relay switch be installed?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"The relay switch must be installed in a dry location to avoid potential damage to the relay switch, GTB 10, and device being switched.\"}}, {\"@type\": \"Question\", \"name\": \"Do relay connections require specific polarity?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Do not connect control wires to the positive side of a power source; follow connection guidance for polarity.\"}}, {\"@type\": \"Question\", \"name\": \"What mounting distance is required from other electronics or cables?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"You must mount the device at least 102 mm (4 in.) from cables and other potential sources of interference.\"}}, {\"@type\": \"Question\", \"name\": \"How do I protect bare wire connections exposed to moisture?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Use heat-shrink type butt connectors or other water-tight connections for bare wires exposed to moisture.\"}}, {\"@type\": \"Question\", \"name\": \"Are there guidelines for extending IN\/OUT wires?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"If you need to extend the IN\/OUT wires, use minimum of 24 AWG (0.08 mm²) wire.\"}}, {\"@type\": \"Question\", \"name\": \"How should unused connectors be protected?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"To prevent corrosion, cover unused connectors with weather caps.\"}}]}\u003c\/script\u003e\u003c!-- \/sr-faq --\u003e","brand":"Garmin","offers":[{"title":"Default Title","offer_id":51626143777105,"sku":"010-13009-01","price":48.94,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0955\/4434\/4913\/files\/garmin-ondeck-relay-switch-12-v-dc-ondecktm-relay-switch-12-v-dc.webp?v=1754729611","url":"https:\/\/www.sailrace.com\/el\/products\/garmin-ondeck-relay-switch-12-v-dc","provider":"SailRACE","version":"1.0","type":"link"}