{"product_id":"lumishore-eclipse-flood-light-4","title":"Lumishore ECLIPSE Flood Light 4\"","description":"\u003cp\u003eECLIPSE Flood Light 4\"\u003c\/p\u003e \u003cp\u003eECLIPSE Flood Light 4\", LS, (60-0467)\u003c\/p\u003e\u003c!-- sr-faq v=1 vendor=lumishore source_sha256=c316002682d44f2a84da9836b590894c83c471afc39e1d876106ff90f7503656 --\u003e\u003cdiv class=\"sr-faq-wrap\" style=\"margin-top:4rem\"\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cdiv class=\"faq-box sr-faq-box\"\u003e\n\u003cdiv class=\"faq-block\"\u003e\u003cdiv class=\"accordion faq-item\"\u003e\u003cdetails\u003e\u003csummary style=\"align-items:center\"\u003e\u003cspan class=\"faq-block__heading\" style=\"flex:1 1 auto;margin:0;padding-right:2rem;font-size:1.5rem;font-weight:700\"\u003eWho is qualified to install and maintain the ECLIPSE Flood Light 4\"?\u003c\/span\u003e\u003csvg class=\"icon icon-filter-two\" width=\"12\" height=\"7\" viewbox=\"0 0 12 7\" fill=\"none\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" aria-hidden=\"true\"\u003e\u003cpath d=\"M10 1.5L6 5.5L2 1.5\" stroke=\"currentColor\" stroke-width=\"2\" stroke-linecap=\"square\"\u003e\u003c\/path\u003e\u003c\/svg\u003e\u003c\/summary\u003e\u003cdiv class=\"faq-block__description\"\u003e\u003cp\u003eIt should only be installed, inspected, and maintained by a qualified electrician, following applicable electrical codes, with power OFF during work.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003cdiv class=\"faq-block\"\u003e\u003cdiv class=\"accordion faq-item\"\u003e\u003cdetails\u003e\u003csummary style=\"align-items:center\"\u003e\u003cspan class=\"faq-block__heading\" style=\"flex:1 1 auto;margin:0;padding-right:2rem;font-size:1.5rem;font-weight:700\"\u003eIn the single switch wiring diagram, what should be done with the yellow wire?\u003c\/span\u003e\u003csvg class=\"icon icon-filter-two\" width=\"12\" height=\"7\" viewbox=\"0 0 12 7\" fill=\"none\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" aria-hidden=\"true\"\u003e\u003cpath d=\"M10 1.5L6 5.5L2 1.5\" stroke=\"currentColor\" stroke-width=\"2\" stroke-linecap=\"square\"\u003e\u003c\/path\u003e\u003c\/svg\u003e\u003c\/summary\u003e\u003cdiv class=\"faq-block__description\"\u003e\u003cp\u003eIn the single switch wiring diagram, the yellow wire is shown as no connection.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003cdiv class=\"faq-block\"\u003e\u003cdiv class=\"accordion faq-item\"\u003e\u003cdetails\u003e\u003csummary style=\"align-items:center\"\u003e\u003cspan class=\"faq-block__heading\" style=\"flex:1 1 auto;margin:0;padding-right:2rem;font-size:1.5rem;font-weight:700\"\u003eIn momentary-switch wiring, which wires are listed as “No connect” and should be isolated?\u003c\/span\u003e\u003csvg class=\"icon icon-filter-two\" width=\"12\" height=\"7\" viewbox=\"0 0 12 7\" fill=\"none\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" aria-hidden=\"true\"\u003e\u003cpath d=\"M10 1.5L6 5.5L2 1.5\" stroke=\"currentColor\" stroke-width=\"2\" stroke-linecap=\"square\"\u003e\u003c\/path\u003e\u003c\/svg\u003e\u003c\/summary\u003e\u003cdiv class=\"faq-block__description\"\u003e\u003cp\u003eThe manual states RED, WHT, and BLU are no-connect and any unused wires should be isolated.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003cdiv class=\"faq-block\"\u003e\u003cdiv class=\"accordion faq-item\"\u003e\u003cdetails\u003e\u003csummary style=\"align-items:center\"\u003e\u003cspan class=\"faq-block__heading\" style=\"flex:1 1 auto;margin:0;padding-right:2rem;font-size:1.5rem;font-weight:700\"\u003eWhen wiring multiple lights with a LUX module, how should the black wires be connected?\u003c\/span\u003e\u003csvg class=\"icon icon-filter-two\" width=\"12\" height=\"7\" viewbox=\"0 0 12 7\" fill=\"none\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" aria-hidden=\"true\"\u003e\u003cpath d=\"M10 1.5L6 5.5L2 1.5\" stroke=\"currentColor\" stroke-width=\"2\" stroke-linecap=\"square\"\u003e\u003c\/path\u003e\u003c\/svg\u003e\u003c\/summary\u003e\u003cdiv class=\"faq-block__description\"\u003e\u003cp\u003eConnect the black wire from each light and the LUX Module to a common ground.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003cdiv class=\"faq-block\"\u003e\u003cdiv class=\"accordion faq-item\"\u003e\u003cdetails\u003e\u003csummary style=\"align-items:center\"\u003e\u003cspan class=\"faq-block__heading\" style=\"flex:1 1 auto;margin:0;padding-right:2rem;font-size:1.5rem;font-weight:700\"\u003eWhat bracket hole size\/fastener is specified for bracket mounting?\u003c\/span\u003e\u003csvg class=\"icon icon-filter-two\" width=\"12\" height=\"7\" viewbox=\"0 0 12 7\" fill=\"none\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" aria-hidden=\"true\"\u003e\u003cpath d=\"M10 1.5L6 5.5L2 1.5\" stroke=\"currentColor\" stroke-width=\"2\" stroke-linecap=\"square\"\u003e\u003c\/path\u003e\u003c\/svg\u003e\u003c\/summary\u003e\u003cdiv class=\"faq-block__description\"\u003e\u003cp\u003eThe bracket uses a 6.5 mm hole suitable for an M6 bolt (supplied).\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003cdiv class=\"faq-block\"\u003e\u003cdiv class=\"accordion faq-item\"\u003e\u003cdetails\u003e\u003csummary style=\"align-items:center\"\u003e\u003cspan class=\"faq-block__heading\" style=\"flex:1 1 auto;margin:0;padding-right:2rem;font-size:1.5rem;font-weight:700\"\u003eWhat torque is specified when tightening the light to the bracket?\u003c\/span\u003e\u003csvg class=\"icon icon-filter-two\" width=\"12\" height=\"7\" viewbox=\"0 0 12 7\" fill=\"none\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" aria-hidden=\"true\"\u003e\u003cpath d=\"M10 1.5L6 5.5L2 1.5\" stroke=\"currentColor\" stroke-width=\"2\" stroke-linecap=\"square\"\u003e\u003c\/path\u003e\u003c\/svg\u003e\u003c\/summary\u003e\u003cdiv class=\"faq-block__description\"\u003e\u003cp\u003eTighten the bracket-mounted light to 5 Nm and do not overtighten.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003cdiv class=\"faq-block\"\u003e\u003cdiv class=\"accordion faq-item\"\u003e\u003cdetails\u003e\u003csummary style=\"align-items:center\"\u003e\u003cspan class=\"faq-block__heading\" style=\"flex:1 1 auto;margin:0;padding-right:2rem;font-size:1.5rem;font-weight:700\"\u003eFor flush mounting, what should be checked behind the mounting location?\u003c\/span\u003e\u003csvg class=\"icon icon-filter-two\" width=\"12\" height=\"7\" viewbox=\"0 0 12 7\" fill=\"none\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" aria-hidden=\"true\"\u003e\u003cpath d=\"M10 1.5L6 5.5L2 1.5\" stroke=\"currentColor\" stroke-width=\"2\" stroke-linecap=\"square\"\u003e\u003c\/path\u003e\u003c\/svg\u003e\u003c\/summary\u003e\u003cdiv class=\"faq-block__description\"\u003e\u003cp\u003eBefore flush mounting, make sure there are no obstructions behind the chosen light location.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003cdiv class=\"faq-block\"\u003e\u003cdiv class=\"accordion faq-item\"\u003e\u003cdetails\u003e\u003csummary style=\"align-items:center\"\u003e\u003cspan class=\"faq-block__heading\" style=\"flex:1 1 auto;margin:0;padding-right:2rem;font-size:1.5rem;font-weight:700\"\u003eWhich wire is ground (GND) in the wiring diagram?\u003c\/span\u003e\u003csvg class=\"icon icon-filter-two\" width=\"12\" height=\"7\" viewbox=\"0 0 12 7\" fill=\"none\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" aria-hidden=\"true\"\u003e\u003cpath d=\"M10 1.5L6 5.5L2 1.5\" stroke=\"currentColor\" stroke-width=\"2\" stroke-linecap=\"square\"\u003e\u003c\/path\u003e\u003c\/svg\u003e\u003c\/summary\u003e\u003cdiv class=\"faq-block__description\"\u003e\u003cp\u003eThe wiring diagram labels the black wire as ground (GND).\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003cdiv class=\"faq-block\"\u003e\u003cdiv class=\"accordion faq-item\"\u003e\u003cdetails\u003e\u003csummary style=\"align-items:center\"\u003e\u003cspan class=\"faq-block__heading\" style=\"flex:1 1 auto;margin:0;padding-right:2rem;font-size:1.5rem;font-weight:700\"\u003eWho do I contact for help with installation, servicing or advice?\u003c\/span\u003e\u003csvg class=\"icon icon-filter-two\" width=\"12\" height=\"7\" viewbox=\"0 0 12 7\" fill=\"none\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" aria-hidden=\"true\"\u003e\u003cpath d=\"M10 1.5L6 5.5L2 1.5\" stroke=\"currentColor\" stroke-width=\"2\" stroke-linecap=\"square\"\u003e\u003c\/path\u003e\u003c\/svg\u003e\u003c\/summary\u003e\u003cdiv class=\"faq-block__description\"\u003e\u003cp\u003eContact \u003ca href=\"https:\/\/www.sailrace.com\/pages\/contact\"\u003ethe SailRACE team\u003c\/a\u003e — as certified marine experts we're happy to help with product selection, installation and after-sales servicing, before and after your purchase.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003cscript type=\"application\/ld+json\"\u003e{\"@context\": \"https:\/\/schema.org\", \"@type\": \"FAQPage\", \"mainEntity\": [{\"@type\": \"Question\", \"name\": \"Who is qualified to install and maintain the ECLIPSE Flood Light 4\\\"?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"It should only be installed, inspected, and maintained by a qualified electrician, following applicable electrical codes, with power OFF during work.\"}}, {\"@type\": \"Question\", \"name\": \"In the single switch wiring diagram, what should be done with the yellow wire?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"In the single switch wiring diagram, the yellow wire is shown as no connection.\"}}, {\"@type\": \"Question\", \"name\": \"In momentary-switch wiring, which wires are listed as “No connect” and should be isolated?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"The manual states RED, WHT, and BLU are no-connect and any unused wires should be isolated.\"}}, {\"@type\": \"Question\", \"name\": \"When wiring multiple lights with a LUX module, how should the black wires be connected?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Connect the black wire from each light and the LUX Module to a common ground.\"}}, {\"@type\": \"Question\", \"name\": \"What bracket hole size\/fastener is specified for bracket mounting?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"The bracket uses a 6.5 mm hole suitable for an M6 bolt (supplied).\"}}, {\"@type\": \"Question\", \"name\": \"What torque is specified when tightening the light to the bracket?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Tighten the bracket-mounted light to 5 Nm and do not overtighten.\"}}, {\"@type\": \"Question\", \"name\": \"For flush mounting, what should be checked behind the mounting location?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Before flush mounting, make sure there are no obstructions behind the chosen light location.\"}}, {\"@type\": \"Question\", \"name\": \"Which wire is ground (GND) in the wiring diagram?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"The wiring diagram labels the black wire as ground (GND).\"}}, {\"@type\": \"Question\", \"name\": \"Who do I contact for help with installation, servicing or advice?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Contact the SailRACE team — as certified marine experts we're happy to help with product selection, installation and after-sales servicing, before and after your purchase.\"}}]}\u003c\/script\u003e\u003c!-- \/sr-faq --\u003e","brand":"Lumishore","offers":[{"title":"Standard","offer_id":53131992760657,"sku":"010-04458-00","price":930.42,"currency_code":"BRL","in_stock":true},{"title":"Black","offer_id":53131992793425,"sku":"010-04631-00","price":974.69,"currency_code":"BRL","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0955\/4434\/4913\/files\/cf-lg_96a7776b-8229-4123-83a2-4eb2b0b5fdb7.jpg?v=1772043857","url":"https:\/\/www.sailrace.com\/pt-br\/products\/lumishore-eclipse-flood-light-4","provider":"SailRACE","version":"1.0","type":"link"}