{"product_id":"garmin-empirbus-nxt-dcm","title":"Garmin EmpirBus NXT DCM","description":"\u003cp\u003eAn EmpiriBus digital switching system consists of one or more compact digital DCMs. The DCM supports several circuits that are customized to meet the exact needs of the equipment being controlled. Each DCM is connected to the existing NMEA 2000® main network cable, allowing it to communicate with the other Garmin DCMs and MFDs through a web viewing unit on the Garmin Network.\u003c\/p\u003e \u003cp\u003eWith multiple ranges and input capabilities, the NXT DCM device is an extremely versatile and cost-effective means of having full control of the boat. Small in size, it is easy to install and maintain.\u003c\/p\u003e \u003cp\u003eAll output channels are electronically protected and are protected against undercurrents, in addition to being equipped with soft start\/stop systems. The channels can be dimmed electronically and drive complex loads such as LED lighting or windshield wipers directly.\u003c\/p\u003e \u003ch3\u003eSpecifications:\u003c\/h3\u003e \u003ctable style=\"height: 1217px\" width=\"863\"\u003e \u003ctbody\u003e \u003ctr\u003e \u003ctd\u003eMisc\u003c\/td\u003e \u003ctd\u003e \u003ch4\u003eDescription\u003c\/h4\u003e \u003ctable\u003e \u003ccolgroup\u003e \u003ccol width=\"33%\"\u003e \u003ccol width=\"67%\"\u003e \u003c\/colgroup\u003e \u003ctbody\u003e \u003ctr\u003e \u003ctd\u003eDimensions (An. x Al. x Pr.)\u003c\/td\u003e \u003ctd\u003e230 X 106 X 38 mm (9,1″ X 4,2″ X 1,5″)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eWeight\u003c\/td\u003e \u003ctd\u003e400 g (14,1 oz)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eClassification of the water in the box\u003c\/td\u003e \u003ctd\u003eIP65\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eAmbient temperature\u003c\/td\u003e \u003ctd\u003eDe -20 °C a 55 °C\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eCommunication\u003c\/td\u003e \u003ctd\u003eRed CAN-bus NMEA 2000®, LEN-0\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003ch4\u003eDepartures\u003c\/h4\u003e \u003ctable\u003e \u003ccolgroup\u003e \u003ccol width=\"33%\"\u003e \u003ccol width=\"67%\"\u003e \u003c\/colgroup\u003e \u003ctbody\u003e \u003ctr\u003e \u003ctd\u003eAlto lateral\u003c\/td\u003e \u003ctd\u003e13 channels of 10 A, 7 channels of 5 A\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003ch4\u003eDigital ticket\u003c\/h4\u003e \u003ctable\u003e \u003ccolgroup\u003e \u003ccol width=\"33%\"\u003e \u003ccol width=\"67%\"\u003e \u003c\/colgroup\u003e \u003ctbody\u003e \u003ctr\u003e \u003ctd\u003eGrounding switch input\u003c\/td\u003e \u003ctd\u003e15\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eMonitor of the bilde bomb\u003c\/td\u003e \u003ctd\u003e2\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003ch4\u003eAnalog input\u003c\/h4\u003e \u003ctable\u003e \u003ccolgroup\u003e \u003ccol width=\"33%\"\u003e \u003ccol width=\"67%\"\u003e \u003c\/colgroup\u003e \u003ctbody\u003e \u003ctr\u003e \u003ctd\u003eVoltios\u003c\/td\u003e \u003ctd\u003e3 a 0-16 V +\/-1 %\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eResistance\u003c\/td\u003e \u003ctd\u003e2 a 0-1500 ohmios +\/-5 %\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003ch4\u003ePower Supply\u003c\/h4\u003e \u003ctable\u003e \u003ccolgroup\u003e \u003ccol width=\"33%\"\u003e \u003ccol width=\"67%\"\u003e \u003c\/colgroup\u003e \u003ctbody\u003e \u003ctr\u003e \u003ctd\u003eMaximum current\u003c\/td\u003e \u003ctd\u003e50 A\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003ePower consumption off\u003c\/td\u003e \u003ctd\u003e60 mA\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eSupply voltage (12 V)\u003c\/td\u003e \u003ctd\u003e9-16 V cc\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003ch4\u003eConnector\u003c\/h4\u003e \u003ctable\u003e \u003ccolgroup\u003e \u003ccol width=\"33%\"\u003e \u003ccol width=\"67%\"\u003e \u003c\/colgroup\u003e \u003ctbody\u003e \u003ctr\u003e \u003ctd\u003eNMEA 2000®\u003c\/td\u003e \u003ctd\u003eMacro micro M12 de 5 pines\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eChannels\u003c\/td\u003e \u003ctd\u003eMolex MX150 L 16 Circuits\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003ePower terminal\u003c\/td\u003e \u003ctd\u003ePerno M6\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e\u003c!-- sr-faq v=1 vendor=garmin source_sha256=24ef9588270fefb321dc0c2603fc397b7d5d863746b91f3b8c62408d41e627f3 --\u003e\u003ch3\u003eFAQs\u003c\/h3\u003e\u003cdetails\u003e\u003csummary\u003eWhat should be documented for system installation?\u003c\/summary\u003e\u003cdiv\u003e\u003cp\u003eDocument all system design and keep it updated for commissioning and future maintenance.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails\u003e\u003csummary\u003eCan the unit casing be opened for installation or inspection?\u003c\/summary\u003e\u003cdiv\u003e\u003cp\u003eNo, the unit should not be opened or the casing removed as it will compromise the environmental seal and void the warranty.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails\u003e\u003csummary\u003eAre standard system fuses or circuit breakers required?\u003c\/summary\u003e\u003cdiv\u003e\u003cp\u003eThe power source for installation must be protected using a suitably rated fuse or automatic circuit breaker.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails\u003e\u003csummary\u003eShould the power supply be off during installation?\u003c\/summary\u003e\u003cdiv\u003e\u003cp\u003eYes, always ensure the power supply is switched off before starting installation. Do not connect\/disconnect with power on.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails\u003e\u003csummary\u003eAre software updates or manuals required for installation or operation?\u003c\/summary\u003e\u003cdiv\u003e\u003cp\u003eCheck the EmpirBus website for the latest software releases and handbooks to ensure correct operation.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails\u003e\u003csummary\u003eCan I extend or cut cables during installation?\u003c\/summary\u003e\u003cdiv\u003e\u003cp\u003eCables should not be cut or extended unless this is specifically detailed in the installation manual.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails\u003e\u003csummary\u003eHow should the product be grounded during installation?\u003c\/summary\u003e\u003cdiv\u003e\u003cp\u003eThe device must be correctly grounded according to instructions before power is applied, to ensure safety and proper operation.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails\u003e\u003csummary\u003eIs this unit suitable for positive ground electrical systems?\u003c\/summary\u003e\u003cdiv\u003e\u003cp\u003eDo not connect the unit to a positive ground system as this may cause damage or safety issues.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails\u003e\u003csummary\u003eShould a fuse or circuit breaker be used on the power source?\u003c\/summary\u003e\u003cdiv\u003e\u003cp\u003eEnsure the power source is adequately protected with a suitably rated fuse or automatic circuit breaker.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cscript type=\"application\/ld+json\"\u003e{\"@context\": \"https:\/\/schema.org\", \"@type\": \"FAQPage\", \"mainEntity\": [{\"@type\": \"Question\", \"name\": \"What should be documented for system installation?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Document all system design and keep it updated for commissioning and future maintenance.\"}}, {\"@type\": \"Question\", \"name\": \"Can the unit casing be opened for installation or inspection?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"No, the unit should not be opened or the casing removed as it will compromise the environmental seal and void the warranty.\"}}, {\"@type\": \"Question\", \"name\": \"Are standard system fuses or circuit breakers required?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"The power source for installation must be protected using a suitably rated fuse or automatic circuit breaker.\"}}, {\"@type\": \"Question\", \"name\": \"Should the power supply be off during installation?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Yes, always ensure the power supply is switched off before starting installation. Do not connect\/disconnect with power on.\"}}, {\"@type\": \"Question\", \"name\": \"Are software updates or manuals required for installation or operation?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Check the EmpirBus website for the latest software releases and handbooks to ensure correct operation.\"}}, {\"@type\": \"Question\", \"name\": \"Can I extend or cut cables during installation?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Cables should not be cut or extended unless this is specifically detailed in the installation manual.\"}}, {\"@type\": \"Question\", \"name\": \"How should the product be grounded during installation?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"The device must be correctly grounded according to instructions before power is applied, to ensure safety and proper operation.\"}}, {\"@type\": \"Question\", \"name\": \"Is this unit suitable for positive ground electrical systems?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Do not connect the unit to a positive ground system as this may cause damage or safety issues.\"}}, {\"@type\": \"Question\", \"name\": \"Should a fuse or circuit breaker be used on the power source?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Ensure the power source is adequately protected with a suitably rated fuse or automatic circuit breaker.\"}}]}\u003c\/script\u003e\u003c!-- \/sr-faq --\u003e","brand":"Garmin","offers":[{"title":"Default Title","offer_id":51626142138705,"sku":"010-02220-08","price":1816.05,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0955\/4434\/4913\/files\/garmin-empirbus-nxt-dcm-empirbustm-nxt-dcm.webp?v=1754729567","url":"https:\/\/www.sailrace.com\/ru-caucasus\/products\/garmin-empirbus-nxt-dcm","provider":"SailRACE","version":"1.0","type":"link"}